Unlike other cables, fireplace resistant cables should work even when immediately uncovered to the fire to maintain important Life Safety and Fire Fighting gear working: Fire alarms, Emergency Lighting, Emergency Communication, Fire Sprinkler pumps, Fireman’s Lift sub-main, Smoke extraction followers, Smoke dampers, Stair pressurization followers, Emergency Generator circuits and so forth.
In order to classify electrical cables as fire resistant they’re required to undergo testing and certification. Perhaps the first widespread hearth tests on cables had been IEC 331: 1970 and later BS6387:1983 which adopted a fuel ribbon burner take a look at to provide a flame in which cables have been positioned.
Since the revision of BS6387 in 1994 there have been eleven enhancements, revisions or new take a look at requirements introduced by British Standards for use and software of Fire Resistant cables however none of those seem to deal with the core issue that fireside resistant cables the place tested to frequent British and IEC flame test standards usually are not required to carry out to the same fireplace performance time-temperature profiles as every other structure, system or element in a constructing. Specifically, where fire resistant structures, methods, partitions, fireplace doors, hearth penetrations fireplace barriers, flooring, walls etc. are required to be fire rated by building rules, they’re tested to the Standard Time Temperature protocol of BS476 components 20 to 23 (also often recognized as ISO834-1, ASNZS1530pt4, EN1363-1 and in America and Canada ASTM E119-75).
These checks are performed in giant furnaces to copy real post flashover fire environments. Interestingly, Fire Resistant cable take a look at requirements like BS 6387CWZ, SS299, IEC 60331 BS8343-1 and 2, BS8491 only require cables to be uncovered to a flame in air and to lower final test temperatures (than required by BS476 pts 20 to 23). Given Fire Resistant cables are more doubtless to be exposed in the identical fire, and are needed to ensure all Life Safety and Fire Fighting methods remain operational, this fact is probably surprising.
Contrastingly in Germany, Belgium, Australia, New Zealand, USA and Canada Fire Resistant cable methods are required to be examined to the identical fire Time Temperature protocol as all other building elements and that is the Standard Time Temperature protocol to BS476pts 20-23, IS0 834-1, EN1363-1 or ASTM E119-75 in USA.
The committees developing the usual drew on the guidance given from the International Fire Prevention Congress held in London in July 1903 and the measurements of furnace temperatures made in lots of fireplace checks carried out within the UK, Germany and the United States. The tests had been described in a collection of “Red Books” issued by the British Fire Prevention Committee after 1903 in addition to those from the German Royal Technical Research Laboratory. The finalization of the ASTM normal was heavily influenced by Professor I.H. Woolson, a Consulting Engineer of the USA National Board of Fire Underwriters and Chairman of the NFPA committee in Fire Resistive Construction who had carried out many tests at Columbia University and Underwriters Laboratories in Chicago. The small time temperature differences between the International ISO 834-1 take a look at as we know it at present and the America ASTM E119 / NFPA 251 exams likely stemmed from this time.
Image courtesy of MICC Ltd.
The curve as we see it today (see graph above) has turn into the usual scale for measurement of fireside test severity and has proved related for many above ground cellulosic buildings. When components, structures, parts or systems are examined, the furnace temperatures are controlled to conform to the curve with a set allowable variance and consideration for preliminary ambient temperatures. The standards require components to be examined in full scale and underneath situations of assist and loading as defined to be able to symbolize as precisely as attainable its features in service.
This Standard Time Temperature testing protocol (see graph right) is adopted by nearly all countries all over the world for fire testing and certification of nearly all constructing constructions, parts, methods and parts with the attention-grabbing exception of fireside resistant cables (exception in USA, Canada, Australia, Germany, Belgium and New Zealand the place hearth resistant cable techniques are required to be examined and approved to the Standard Time Temperature protocol, similar to all different building structures, components and components).
It is necessary to understand that software requirements from BS, IEC, ASNZS, DIN, UL and so on. where fireplace resistive cables are specified to be used, are only ‘minimum’ necessities. We know at present that fires aren’t all the same and research by Universities, Institutions and Authorities around the globe have recognized that Underground and a few Industrial environments can exhibit very totally different fireplace profiles to these in above ground cellulosic buildings. Specifically in confined underground public areas like Road and Rail Tunnels, Underground Shopping centers, Car Parks fireplace temperatures can exhibit a really fast rise time and can attain temperatures well above those in above ground buildings and in far much less time. In USA today electrical wiring techniques are required by NFPA 502 (Road Tunnels, Bridges and different Limited Access Highways) to face up to fireplace temperatures as much as 1,350 Degrees C for 60 minutes and UK British Standard BS8519:2010 clearly identifies underground public areas corresponding to car parks as “Areas of Special Risk” where more stringent take a look at protocols for important electric cable circuits could must be thought of by designers.
Standard Time Temperature curves (Europe and America) plotted against frequent BS and IEC cable exams.
Of course all underground environments whether highway, rail and pedestrian tunnels, or underground public environments like shopping precincts, automotive parks and so forth. may exhibit different fire profiles to these in above ground buildings because In these environments the heat generated by any fireplace can not escape as easily as it would in above floor buildings thus relying more on warmth and smoke extraction tools.
For Metros Road and Rail Tunnels, Hospitals, Health care facilities, Underground public environments like buying precincts, Very High Rise, Theaters, Public Halls, Government buildings, Airports etc. that is notably necessary. Evacuation of those public environments is commonly slow even during emergencies, and it is our responsibility to ensure everyone is given the easiest chance of protected egress during fireplace emergencies.
It is also understood right now that copper Fire Resistant cables the place installed in galvanized metal conduit can fail prematurely throughout fireplace emergency due to a reaction between the copper conductors and zinc galvanizing contained in the metallic conduit. In 2012 United Laboratories (UL®) in America eliminated all certification for Fire Resistive cables where put in in galvanized metal conduit for this reason:
UL® Quote: “A concern was brought to our consideration related to the efficiency of these merchandise within the presence of zinc. We validated this finding. As a results of this, we modified our Guide Information to indicate that all conduit and conduit fittings that come in contact with fireplace resistive cables ought to have an inside coating free of zinc”.
Time temperature profile of tunnel fires using vehicles, HGV trailers with totally different cargo and rail carriages. Graph extract: Haukur Ingason and Anders Lonnermark of the Swedish National Testing and Research Institute who presented the paper on the First International Symposium in Prague 2004: Safe and Reliable Tunnels.
It would appear that some Standards authorities around the world could have to review the current test methodology presently adopted for fireplace resistive cable testing and perhaps align the efficiency of Life Safety and Fire Fighting wiring methods with that of all the opposite fire resistant buildings, elements and methods so that Architects, building designers and engineers know that when they want a fire score that the important wiring system might be equally rated.
For many power, control, communication and information circuits there may be one technology obtainable which may meet and surpass all present hearth tests and purposes. It is an answer which is frequently used in demanding public buildings and has been employed reliably for over eighty years. Top secret can provide a total and complete answer to all the problems related to the fireplace security dangers of contemporary versatile natural polymer cables.
The metal jacket, magnesium oxide insulation and conductors of MICC cables make positive the cable is successfully fireplace proof. Bare MICC cables have no organic content material so merely can not propagate flame or generate any smoke. The zero fuel-load of those MICC cables ensures no heat is added to the fireplace and no oxygen is consumed. Being inorganic these MICC cables cannot generate any halogen or poisonous gasses in any respect including Carbon Monoxide. MICC cable designs can meet all of the present and building fireplace resistance efficiency requirements in all countries and are seeing a significant enhance in use globally.
Many engineers have beforehand thought of MICC cable know-how to be “old school’ however with the new research in fire efficiency MICC cable system are now proven to have far superior hearth performances than any of the newer extra modern versatile fire resistant cables.
For further information, go to www.temperature-house.com